Question about: "rate-limit: stop limiting responses to 1.1.1.0/24 for www.example.com"
Tony Finch
dot at dotat.at
Thu Jan 4 16:22:49 UTC 2018
Tom <tomtux007 at gmail.com> wrote:
> Why does this logentry only appears about 60-65 seconds later, after
> I've stopped the "test"-attack (confirmed multiple times..)?
There's a hardcoded cleanup timeout of 60 seconds. The extra is (I think)
due to the time needed to make the token bucket positive.
Tony.
--
f.anthony.n.finch <dot at dotat.at> http://dotat.at/ - I xn--zr8h punycode
German Bight: Cyclonic 3 or 4, increasing 5 or 6, occasionally 7 to severe
gale 9 in far southwest. Moderate, occasionally rough in southwest. Rain or
showers. Good occasionally poor.
More information about the bind-users
mailing list