a question about the serial

Mark Andrews marka at isc.org
Tue Aug 23 01:48:48 UTC 2016


In message <20160823015248.02edc3f2 at workstation.bitcorner.intern>, Andreas Meye
r writes:
> Andreas Meyer <a.meyer at nimmini.de> schrieb am 23.08.16 um 00:18:02 Uhr:
>
> > > After reloading or stopping and starting the serial is not changed
> > > and shows a value serial 2016080310.
> > >
> > > Why is the serial not updated?
> >
> > I found out that the signed zone is not updated with a reload or
> > restart of bind9 but with a rndc reload it is.
>
> No, it is not :(
>
>   Andreas

The inline serial is mostly independent of the raw zone file.

BIND 9.11 has: rndc signing -serial <value> zone [class [view]]