EDNS - edns-udp-size and max-udp-size
Mark Andrews
Mark_Andrews at isc.org
Wed Feb 25 00:40:45 UTC 2009
In message <20090225002133.GB99327 at isc.org>, Evan Hunt writes:
> > The code just looks at the number of timeouts not at what
> > size was sent in the initial query. triededns512() records
> > when the DNS_FETCHOPT_EDNS512 has been set not when the
> > initial query advertised a receive buffer of 512 bytes.
>
> But, if the initial query uses a receive buffer of 512 bytes or less,
> can't we just set DNS_FETCHOPT_EDNS512 straight off and save a step?
>
> eh
One could but, as was evident from the logs, it would cause
named to switch back to plain DNS more often when it didn't
need to.
Mark
--
Mark Andrews, ISC