performance issues with 9.5.0-P1
JINMEI Tatuya / 神明達哉
Jinmei_Tatuya at isc.org
Mon Jul 14 18:13:58 UTC 2008
At Mon, 14 Jul 2008 12:48:43 -0400,
Jim Gogan <gogan at email.unc.edu> wrote:
> Wondering if anyone else has encountered what I would consider
> significant performance issues with BIND 9.5.0-P1. On three different
> Solaris systems, each one averaging about 270-280 queries per second,
> since the patch install, the load average has gone from acceptable to
> not-so-much (now averaging between 2-4) with named hitting between
> 49-90% of the CPU.
>
> Just curious to see if anyone else is seeing this or if it's just us.
If you have upgraded from 9.4 or 9.3 (or even older) to 9.5.0-P1,
please check your max-cache-size value. 9.5 has a pretty small
default value (32MB) for middle-to-large scale caching servers, and it
can make the server unnecessarily heavy-load.
---
JINMEI, Tatuya
Internet Systems Consortium, Inc.
More information about the bind-users
mailing list