4 second delay on lookups
Gavin Hamill
gdh at acentral.co.uk
Mon Jul 10 13:26:50 UTC 2006
JINMEI Tatuya / 神明達哉 wrote:
> The -4 option is available only in 9.3 and later.
>
> Your options are:
> - upgrade BIND9 to 9.2.5 or 9.3.2 (then you don't even need to specify
> -4)
> - rebuild 9.2.4 with --disable-ipv6
I did try rebuilding the 9.2.4 with --disable-ipv6 but had similar
problems (using tcpdump I noticed any AAAA lookup from LAN clients
failed after 4 secs, but all A lookups executed immediately - a
half-way-house...)
So I decided to give the 9.3.2 package from backports.org a whirl and
I've not looked back - everything is now resolving immediately.
Usually I like to know more detail and exactly why the problem was
solved, but this time I'm just happy that It Works :)
Cheers,
Gavin.
More information about the bind-users