also-notify
FUJITA Kazutoshi
fujita at soum.co.jp
Mon Dec 10 10:09:06 UTC 2001
From: Oleg Prokopyev <riiki at gu.net>
Subject: Re: also-notify
Date: Mon, 10 Dec 2001 11:49:19 +0200
Message-ID: <3C14851F.93537793 at gu.net>
> brrr.... you did not understand me
> when i changed zone statement adding "also-notify" i forgot to "ndc
> restart" :)
> that was the reason:)
didn't you write you did 'ndc reload'?
'ndc reload' equals to 'kill -HUP named.pid'
and in named(8),
> The following signals have the specified effect when sent to the server
> process using the kill(1) command:
>
> SIGHUP Causes server to read named.conf and reload the database. If
> the server is built with the FORCED_RELOAD compile-time option,
> then SIGHUP will also cause the server to check the serial num-
> ber on all secondary zones; normally, the serial numbers are
> only checked at the SOA-specified intervals.
More information about the bind-users
mailing list