SOA settings
Reindl Harald
h.reindl at thelounge.net
Fri Feb 2 06:48:41 UTC 2018
Am 02.02.2018 um 01:21 schrieb Lyle:
> Bind does default to seconds.
> However this is not the SOA record.
surely, at least a part of it
@ IN SOA srv-rhsoft.rhsoft.net. admin.rhsoft.net. (
2017110901 ; Serial
1800 ; Refresh
600 ; Retry
1814400 ; Expire
900 ; Negative-TTL
);
> On 02/01/18 18:08, lbutlr wrote:
>> I am looking at a config file and seeing:
>>
>> 2017112100 ; serial
>> 1H ; refresh
>> 15 ; retry
>> 1w ; expire
>> 1H ; minimum
>>
>> Is that 15 15 seconds?
>> I'm guess ion it should be 15m?
More information about the bind-users
mailing list