BIND 9.7 Serial Number Decrease Problem
Daniel McDonald
dan.mcdonald at austinenergy.com
Tue Jun 7 13:57:00 UTC 2011
On 6/7/11 7:51 AM, "Barry Finkel" <bsfinkel at anl.gov> wrote:
> There was a zone serial number mismatch, each zone expired three days
> ago, and new zones were transferred from the master. But the zone
> files on disk still have the higher serial numbers. There are no .jnl
> files on the disk. A "dig" on the server for the zone serial numbers
> shows the lower numbers, so BIND has those correct serial numbers.
If you have multiple masters for which this server is a slave, then check
the serial number on all of the masters. I think you will find that one of
them is higher than the other...
> I
> assume that if I stopped BIND (rndc stop) and restarted it, then I
> would again see the serial number mismatches. I can try this during
> the day, as this server is not heavily used. Is there any debugging I
> need to run? Thanks.
--
Daniel J McDonald, CCIE # 2495, CISSP # 78281