Is there a max on the Serial Number?
Bob Vance
bobvance at alumni.caltech.edu
Sat Feb 3 12:59:34 UTC 2001
>Can't you have:
<Year><Month><Day><hour><minute> anymore?
Sure.... but *not*
<century><Year><Month><Day><hour><minute>
(unless the minute never goes over 99 :)
SERIAL is 32 bits, unsigned and can't handle over 10 digits.
The best that you can do is
ccyymmddNN
where NN is a simple sequence number for that day.
This can be a problem if you have more than 99 changes per day, say,
because of DHCP dynamic updates.
OTOH, you could move your serial number *forward* to
yymmddmmmm
now that we're past Y2K (see archives).
But, then what are you gonna do for the year 2043 :)
-------------------------------------------------
Tks | <mailto:BVance at sbm.com>
BV | <mailto:BobVance at alumni.caltech.edu>
Sr. Technical Consultant, SBM, A Gates/Arrow Co.
Vox 770-623-3430 11455 Lakefield Dr.
Fax 770-623-3429 Duluth, GA 30097-1511
=================================================
-----Original Message-----
From: bind-users-bounce at isc.org [mailto:bind-users-bounce at isc.org]On
Behalf Of Lists User
Sent: Saturday, February 03, 2001 12:07 AM
To: bind-users at isc.org
Subject: Is there a max on the Serial Number?
If the serial number in the SOA entry is over 10 digits it gives me the
following error in rndc when I try to so a reload.
For example: 2001020223 will work, but 20010202231 will not.
It gives me the following error:
dns_rdata_fromtext: db.domainname.com:2: near '10800': out of range
Can't you have:
<Year><Month><Day><hour><minute> anymore?
Thanks for any help,
-Steve
More information about the bind-users
mailing list