restart - problem
Joseph S D Yao
jsdy at cospo.osis.gov
Fri Aug 20 17:51:10 UTC 1999
> we are running several nameservers with bind 8.1.2 on solaris 2.6 for a
> few month.
> Six times a day we are reloading them.
> Everything was alright till we made a restart. Now we have the strange
> problem, that some of them don't work any more, even all have the same
> configuration (the same named.conf). If you ask one of them, a time out
> is all you get.
Try sending that one some signal - to get a cache dump, or re-load the
server files, or anything.
There have been reports of servers hanging trying to query specific
other servers. A signal [a real Unix signal vs. a fifo message] will
cause such a "hung" read to break.
I think someone posted a timeout patch here recently ... or mentioned
that 8.2 had it ...
--
Joe Yao jsdy at cospo.osis.gov - Joseph S. D. Yao
COSPO/OSIS Computer Support EMT-B
-----------------------------------------------------------------------
PLEASE ... send or Cc: all "COSPO/OSIS Computer Support"
mail to sys-adm at cospo.osis.gov
-----------------------------------------------------------------------
This message is not an official statement of COSPO policies.
More information about the bind-users